3.3 Electro-acoustic Performance Indexes
3.3.1 The electro-acoustic performance indexes of PAS in every service zone shall be in accordance with those specified in Table 3.3.1.
Table 3.3.1 Electro-acoustic performance indexes of PAS
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_4.jpg?sign=1739347823-0QLBvtZRPoxrsP2VOIKuAPh65TXUh7kw-0-52764da73910282a2854172564542540)
*:The ENSPL of emergency broadcast shall meet the requirements stipulated in item 2,article 3.2.5 of this code.
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_5.jpg?sign=1739347823-4X5Tc8B921pXvXnEs2rz2tNytywoDVjB-0-5f002680274b9d033b9133c5cd2fd5e8)
Figure 3.3.1-1 Tolerance domain of indoor transmission frequency response of business announcement class 1/background broadcast class 1
(the maximum value of the measured curve is set to be 0dB)
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_6.jpg?sign=1739347823-uriQvnHjemQrg2ORWueHMRdOOMXGUPN4-0-39a3a15695190e842edd6be0d0350983)
Figure 3.3.1-2 Tolerance domain of indoor transmission frequency response of business announcement class 2/background broadcast class 2
(the maximum value of the measured curve is set to be 0dB)
![img](https://epubservercos.yuewen.com/7E2126/18000635808208506/epubprivate/OEBPS/Images/txt003_7.jpg?sign=1739347823-B8Z3o39VJBBoMhxuu6XdFjpaVYFtJYlz-0-f0adffa01cf728bda6ee704e39037099)
Figure 3.3.1-3 Tolerance domain of indoor transmission frequency response of business announcement class 3
(the maximum value of the measured curve is set to be 0dB)
3.3.2 For indoor PAS,the relevant architectural acoustic characteristics should comply with the requirements of current national standards GB/T 50356,Code for architectural acoustical design of theater,cinema,and multi-use auditorium and JGJ/T 131,Specification for acoustical design and measurement of gymnasium and stadium.